Analysis of phthalic acid esters in biological samples

[Outline]
Phthalic acid esters (PAEs)1,2, extracted from biological samples with acetonitrile and purified by Florisil-PSA column chromatography, are analyzed by a gas chromatograph/mass spectrometer (GC/MS) qualitatively and quantitatively.
The esters analyzed here are dibutyl phthalate (DBP), butylbenzyl phthalate (BBP), di-2-ethylhexyl phthalate (DEHP), diisooctyl phthalate (DiOP) and diisononyl phthalate (DiNP).
This method can be applied to serum.

[Reagents]
Confirm by chromatography that all the reagents present no problem in PAE analysis.
(i) Organic solvents: n-Hexane, acetonitrile and acetone of PAE analysis grade. Open the seal immediately before use3.
(ii) Anhydrous odium sulfate: Residual pesticide analysis grade; heat to 200Ž for 2 hours and let cool down before use.
(iii) Sodium chloride: PAE analysis grade; heat to 200Ž for 2 hours and let cool down before use.
(iv) Purified water: Distilled water after washing with n-hexane of the PAE analysis grade4.
(v) Florisil: Florisil PR; heat to 200Ž for 2 hours and let cool down before use.
(vi) PSA: Bondesil PSA.
(vii) Standard PAE solutions: Place 20 mg each of standard products in 20 ml measuring flasks and add n-hexane to 20 ml to obtain 1000ƒĘg/ml solutions. Dilute as appropriate.
(viii) Internal standards: Place 20 mg each of standard PAE-d4 in 20 ml measuring flasks and add n-hexane to 20 ml to obtain 1000ƒĘg/ml solutions. Dilute as appropriate.

[Apparatus]
(i) Gas chromatograph/mass spectrometer (GC/MS): A unit capable of selective ion monitoring (SIM) equipped with an ion source by electron ionization and a capillary column (splitless)
(ii) Florisil-PSA column: Fill a glass chromatographic column, 15 mm i.d. and 110 mm long, with 1 g Florisil and 0.5 g PSA and 2 g anhydrous sodium sulfate upon it. Wash the column with 10 ml acetone and 10 ml n-hexane before use.
@